Aplitec.mx

Product Data Sheet
Edition 9.18.2007 Identification no. C370 Sikadur AnchorFix-1 Sikadur® AnchorFix-1 Modified-acrylic anchoring adhesive Description
Sikadur AnchorFix-1 is a two-component, solvent- and styrene-free, modified-acrylic anchor- ing adhesive.
Where to Use
As a fast-curing anchoring adhesive for all grades of rebars, threaded rods, bolts and special fastening systems. Install in concrete and masonry base materials.
Advantages
Low sensitivity to mixing errors.
Can be dispensed/mixed with a standard, good quality caulking gun or sausage gun.
Packaging
10 fl.oz. (300 ml) or 20 fl.oz. (550 ml) two-component collapsible "cartridge in cartridge" system. Ready-to-use with a standard, good quality caulking gun (10 fl.oz.) or sausage gun (20 fl.oz.).
Gel and Curing Times
Cure Time
Limitations
n THE NTSB HAS STATED THAT THIS PRODUCT IS APPROVED FOR SHORT TERM
LOADS ONLY AND SHOULD NOT BE USED IN SUSTAINED TENSILE LOAD ADHESIVE
ANCHORING APPLICATIONS WHERE ADHESIVE FAILURE COULD RESULT IN A
PUBLIC SAFETY RISK. CONSULT A DESIGN PROFESSIONAL PRIOR TO USE.
Technical Data
Shelf Life

Use within 12 months of manufacturing date.
Storage Conditions
Store dry in original unopened packaging in cool conditions at 40°-80°F (4-27°C) and out of direct sunlight. Components ‘A'+'B' mixed: uniform gray Mixing Ratio
Components ‘A':Component ‘B' = 10:1 by volume Consistency
Comp. ‘A'+'B' mixed: non-sag, creamy paste Application Temperatures Substrate and ambient: 14°-86°F (-10°-30°C)
Density (Mixed)
2.75 lbs./gal. (0.33 kg/l) Component A: IRRITANT. Contains epoxy resin, 1-ethenyl-4-methyl benzene, and silica
quartz (sand). Eye irritant. May cause skin/respiratory irritation. Harmful if swallowed.
Component B: IRRITANT, SENSITIZER. Contains benzoyl peroxide, and glycerine. Eye
irritant. May cause skin/respiratory irritation. Prolonged and/or repeated skin contact may cause an allergic reaction/sensitization. Harmful if swallowed.
Cured material, if sanded, may result in exposure to a chemical known to the State of Cali- fornia to cause cancer.
Components A & B
First Aid
Eyes: Flush eyes with water for at least 15 minutes Skin: Immediately flush skin with soap
and water for at least 15 minutes. Ingestion: Do not induce vomiting. Contact a physician.
Inhalation: Remove to fresh air. Contact a physician if symptoms persist. Contact a
physician immediately with all cases if symptoms persist.
Components A & B
Handling and Storage Avoid contact with skin and eyes. Use chemical resistant gloves/goggles/clothing. Use with
adequate general and local exhaust ventilation. In the absence of adequate ventilation, use a properly fitted NIOSH approved ventilator. Wash hands thoroughly after handling product. Remove contaminated clothing and launder before reuse. Store in a cool, dry, well-ventilated Components A & B
In case of spill, wear chemical resistant gloves/goggles/clothing. Ventilate area. In absence of adequate ventilation, use a properly fitted NIOSH respirator. Contain spill and collect with absorbent material and transfer to a sealed container. Dispose of in accordance with appli- cable local, state and federal regulations.
Load Capacities - Threaded Rod
1) Allowable loads are based on a minimum safety factor of 5.33. Higher factors of safety may be war- ranted depending on actual application and job site conditions. Consult a design professional prior to 2) Minimum concrete base material thickness must be 1.5 times the anchor embedment depth. 3) Allowable load of adhesive anchor must be the lesser of bond or steel strength. **For information on the effects of Anchor Spacing and
Edge Distance on adhesive anchor performance, please
contact Sika's Technical Service Department.
Load Capacities -
Rebar Size
Drill Bit
Allowable Tensile
Allowable Tensile Allowable Shear
Bond Strength Min.
Bond Strength
2,000 psi (13.8 MPa)
≥ 2,000 psi.
1) Allowable loads are based 4,000 psi
(13.8 MPa)
on a minimum safety factor of (27.5 MPa)
5.33. Higher factors of safety may be warranted depending on actual application and job site conditions. Consult a design professional prior to 2) Minimum concrete base material thickness must be 1.5 times the anchor embedment 3) Allowable load of adhesive anchor must be the lesser of bond or steel strength.
**For information on the effects of
Anchor Spacing and Edge Distance
on adhesive anchor performance,
please contact Sika's Technical
Methods of Use
Solid Base Material
Blow the hole clean with Drill the hole to the compressed air, brush clean Unscrew the cap.
Pull the red plug.
correct diameter and with a nylon brush and blow depth using a rotary clean again. Hole may be dry hammer drill.
or damp but must be free from standing water.
Insert the mixer nozzle to the far and half fill hole (depending upon Cut the bags to remove Attach the static mixing first part of the application). Withdraw nozzle as extruded adhesive to waste until a you fill the hole. For deep holes uniform color is achieved.
extension tubing can be used.
Prior to use, remove surface contaminants such as oil or grease done slowly with a from anchor to avoid slight twisting mo- inadequate bond. tion. Excess resin Immediately insert should be removed from the mouth then attach the fixture and the anchor hardware.
of the hole before it sets.
tighten the nut.
Hollow Base Material
Blow the hole clean with compressed air, brush clean with a nylon brush either a hammer drill or rotary- and blow clean again. Insert the correct Cut the bags to re- only machine depending upon Hole may be dry or damp perforated screen.
move the red plug.
the substrate.
but must be free from standing water.
Insert mixer nozzle to the Prior to use, remove surface far end of the perforated contaminants such as oil or sleeve and completely grease from anchor to avoid Attach the static mix- fill the sleeve with resin. inadequate bond. Immediately the first part of Withdraw the mixer nozzle insert the anchoring hardware. as the sleeve fills.
This should be done slowly with adhesive to waste until a a slight twisting motion. Leave uniform color is achieved.
the anchor undisturbed until the cure time has elapsed, then attach the fixture and tighten KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY
All information provided by Sika Corporation ("Sika") concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling condi- tions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at www.sikacorp.com or by calling 800-933-7452.
Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Technical
Data Sheet, product label and Material Safety Data Sheet which are available online at www.sikaconstruction.com or by calling Sika's Technical
Service Department at 800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and fol ow the warnings and
instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use.
LIMITED WARRANTY:
Sika warrants this product for one year from date of instal ation to be free from manufacturing defects and to meet the
technical properties on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES ExPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEqUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE
FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
Visit our website at www.sikaconstruction.com
Regional Information and Sales Centers. For the location of your nearest Sika sales office, contact your regional center.
Sika Corporation
Sika Canada Inc.
Sika Mexicana S.A. de C.V.
201 Polito Avenue 601 Delmar Avenue Carretera Libre Celaya Km. 8.5 Lyndhurst, NJ 07071 Fracc. Industrial Balvanera Phone: 800-933-7452 Corregidora, Queretaro Fax: 201-933-6225 Phone: 514-697-2610 Fax: 514-694-2792 Phone: 52 442 2385800 Fax: 52 442 2250537 Sika and Sikadur are registered trademarks. Printed in Canada.

Source: http://aplitec.mx/tienda/download/pdf/anchorfix1.pdf

Introduction

Ethio. J. Appl. Sci. Technol. Vol(4):65-75(2013) 65 ORIGINAL ARTICLE In vitro Nematicidal (Anthelmintic) Property of the Seed Extracts of Anamirta cocculus (Linn.) Against Pheretima posthuma (L. Vaill.) Umer Qadir and Paul, V.I.* Department of Zoology, Annamalai University, Annamalainagar 608 002, Tamil Nadu,

slep.com.br

Pituitary 7: 83–87, 2004  2005 Springer Science + Business Media, Inc. Manufactured in The Netherlands. Pituitary Apoplexy During Therapy with Cabergoline in anAdolescent Male with Prolactin-Secreting Macroadenoma Mirta Knoepfelmacher, Miriam C. Gomes, Maria E.Melo, and Berenice B. MendoncaDepartment of Endocrinology, Hospital das Cl´ınicas, Universityof S ˜ao Paulo Medical School, S ˜ao Paulo, Brasil