Aplitec.mx
Product Data Sheet
Edition 9.18.2007
Identification no. C370
Sikadur AnchorFix-1
Sikadur® AnchorFix-1
Modified-acrylic anchoring adhesive
Description
Sikadur AnchorFix-1 is a two-component, solvent- and styrene-free, modified-acrylic anchor-
ing adhesive.
Where to Use
As a fast-curing anchoring adhesive for all grades of rebars, threaded rods, bolts and special
fastening systems. Install in concrete and masonry base materials.
Advantages
Low sensitivity to mixing errors.
Can be dispensed/mixed with a standard, good quality caulking gun or sausage gun.
Packaging
10 fl.oz. (300 ml) or 20 fl.oz. (550 ml) two-component collapsible "cartridge in cartridge"
system. Ready-to-use with a standard, good quality caulking gun (10 fl.oz.) or sausage gun
(20 fl.oz.).
Gel and Curing Times
Cure Time
Limitations
n
THE NTSB HAS STATED THAT THIS PRODUCT IS APPROVED FOR SHORT TERM
LOADS ONLY AND SHOULD NOT BE USED IN SUSTAINED TENSILE LOAD ADHESIVE
ANCHORING APPLICATIONS WHERE ADHESIVE FAILURE COULD RESULT IN A
PUBLIC SAFETY RISK. CONSULT A DESIGN PROFESSIONAL PRIOR TO USE.
Technical Data
Shelf Life
Use within 12 months of manufacturing date.
Storage Conditions
Store dry in original unopened packaging in cool conditions
at 40°-80°F (4-27°C) and out of direct sunlight.
Components ‘A'+'B' mixed: uniform gray
Mixing Ratio
Components ‘A':Component ‘B' = 10:1 by volume
Consistency
Comp. ‘A'+'B' mixed: non-sag, creamy paste
Application Temperatures Substrate and ambient: 14°-86°F (-10°-30°C)
Density (Mixed)
2.75 lbs./gal. (0.33 kg/l)
Component A: IRRITANT. Contains epoxy resin, 1-ethenyl-4-methyl benzene, and silica
quartz (sand). Eye irritant. May cause skin/respiratory irritation. Harmful if swallowed.
Component B: IRRITANT, SENSITIZER. Contains benzoyl peroxide, and glycerine. Eye
irritant. May cause skin/respiratory irritation. Prolonged and/or repeated skin contact may
cause an allergic reaction/sensitization. Harmful if swallowed.
Cured material, if sanded, may result in exposure to a chemical known to the State of Cali-
fornia to cause cancer.
Components A & B
First Aid
Eyes: Flush eyes with water for at least 15 minutes
Skin: Immediately flush skin with soap
and water for at least 15 minutes.
Ingestion: Do not induce vomiting. Contact a physician.
Inhalation: Remove to fresh air. Contact a physician if symptoms persist.
Contact a
physician immediately with all cases if symptoms persist.
Components A & B
Handling and Storage Avoid contact with skin and eyes. Use chemical resistant gloves/goggles/clothing. Use with
adequate general and local exhaust ventilation. In the absence of adequate ventilation, use
a properly fitted NIOSH approved ventilator. Wash hands thoroughly after handling product.
Remove contaminated clothing and launder before reuse. Store in a cool, dry, well-ventilated
Components A & B
In case of spill, wear chemical resistant gloves/goggles/clothing. Ventilate area. In absence
of adequate ventilation, use a properly fitted NIOSH respirator. Contain spill and collect with
absorbent material and transfer to a sealed container. Dispose of in accordance with appli-
cable local, state and federal regulations.
Load Capacities - Threaded Rod
1) Allowable loads are based on a minimum safety
factor of 5.33. Higher factors of safety may be war-
ranted depending on actual application and job site
conditions. Consult a design professional prior to
2) Minimum concrete base material thickness must
be 1.5 times the anchor embedment depth.
3) Allowable load of adhesive anchor must be the
lesser of bond or steel strength.
**For information on the effects of Anchor Spacing and
Edge Distance on adhesive anchor performance, please
contact Sika's Technical Service Department.
Load Capacities -
Rebar Size
Drill Bit
Allowable Tensile
Allowable Tensile Allowable Shear
Bond Strength Min.
Bond Strength
2,000 psi (13.8 MPa)
≥ 2,000 psi.
1) Allowable loads are based
4,000 psi
(13.8 MPa)
on a minimum safety factor of
(27.5 MPa)
5.33. Higher factors of safety
may be warranted depending
on actual application and job
site conditions. Consult a
design professional prior to
2) Minimum concrete base
material thickness must be 1.5
times the anchor embedment
3) Allowable load of adhesive
anchor must be the lesser of
bond or steel strength.
**For information on the effects of
Anchor Spacing and Edge Distance
on adhesive anchor performance,
please contact Sika's Technical
Methods of Use
Solid Base Material
Blow the hole clean with
Drill the hole to the
compressed air, brush clean
Unscrew the cap.
Pull the red plug.
correct diameter and
with a nylon brush and blow
depth using a rotary
clean again. Hole may be dry
hammer drill.
or damp but must be free from
standing water.
Insert the mixer
nozzle to the far
and half fill hole (depending upon
Cut the bags to remove
Attach the static mixing
first part of the
application). Withdraw nozzle as
extruded adhesive to waste until a
you fill the hole. For deep holes
uniform color is achieved.
extension tubing can be used.
Prior to use, remove
surface contaminants
such as oil or grease
done slowly with a
from anchor to avoid
slight twisting mo-
inadequate bond.
tion. Excess resin
Immediately insert
should be removed from the mouth
then attach the fixture and
the anchor hardware.
of the hole before it sets.
tighten the nut.
Hollow Base Material
Blow the hole clean with
compressed air, brush
clean with a nylon brush
either a hammer drill or rotary-
and blow clean again.
Insert the correct
Cut the bags to re-
only machine depending upon
Hole may be dry or damp
perforated screen.
move the red plug.
the substrate.
but must be free from
standing water.
Insert mixer nozzle to the
Prior to use, remove surface
far end of the perforated
contaminants such as oil or
sleeve and completely
grease from anchor to avoid
Attach the static mix-
fill the sleeve with resin.
inadequate bond. Immediately
the first part of
Withdraw the mixer nozzle
insert the anchoring hardware.
as the sleeve fills.
This should be done slowly with
adhesive to waste until a
a slight twisting motion. Leave
uniform color is achieved.
the anchor undisturbed until the
cure time has elapsed, then
attach the fixture and tighten
KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY
All information provided by Sika Corporation ("Sika") concerning Sika products, including but not limited to, any recommendations and advice relating to the
application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled
and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling condi-
tions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice,
recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice,
recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application
and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice.
All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at
www.sikacorp.com or by calling 800-933-7452.
Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Technical
Data Sheet, product label and Material Safety Data Sheet which are available online at www.sikaconstruction.com or by calling Sika's Technical
Service Department at 800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and fol ow the warnings and
instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use.
LIMITED WARRANTY: Sika warrants this product for one year from date of instal ation to be free from manufacturing defects and to meet the
technical properties on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended
use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor.
NO OTHER WARRANTIES ExPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEqUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE
FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
Visit our website at www.sikaconstruction.com
Regional Information and Sales Centers. For the location of your nearest Sika sales office, contact your regional center.
Sika Corporation
Sika Canada Inc.
Sika Mexicana S.A. de C.V.
201 Polito Avenue
601 Delmar Avenue
Carretera Libre Celaya Km. 8.5
Lyndhurst, NJ 07071
Fracc. Industrial Balvanera
Phone: 800-933-7452
Corregidora, Queretaro
Fax: 201-933-6225
Phone: 514-697-2610
Fax: 514-694-2792
Phone: 52 442 2385800
Fax: 52 442 2250537
Sika and Sikadur are registered
trademarks. Printed in Canada.
Source: http://aplitec.mx/tienda/download/pdf/anchorfix1.pdf
Ethio. J. Appl. Sci. Technol. Vol(4):65-75(2013) 65 ORIGINAL ARTICLE In vitro Nematicidal (Anthelmintic) Property of the Seed Extracts of Anamirta cocculus (Linn.) Against Pheretima posthuma (L. Vaill.) Umer Qadir and Paul, V.I.* Department of Zoology, Annamalai University, Annamalainagar 608 002, Tamil Nadu,
Pituitary 7: 83–87, 2004 2005 Springer Science + Business Media, Inc. Manufactured in The Netherlands. Pituitary Apoplexy During Therapy with Cabergoline in anAdolescent Male with Prolactin-Secreting Macroadenoma Mirta Knoepfelmacher, Miriam C. Gomes, Maria E.Melo, and Berenice B. MendoncaDepartment of Endocrinology, Hospital das Cl´ınicas, Universityof S ˜ao Paulo Medical School, S ˜ao Paulo, Brasil